Add-on · Bidirectional equipment control

Automate your winery without replacing your equipment

The app reads what every machine is doing (when it starts, how much it processed) and sends it commands: start the bottling line, stop a pump, change the chiller setpoint. Critical ones need approval from another authorized person or your QR-verified presence.

Compatibility

Works with what you already have on the floor

Five integration tiers, from the manufacturer's cloud down to manual logging. No machine is left out of the book.

TierHow it connectsWhat you get
AManufacturer platform (cloud)Data reading with the winery's credentials; no commands
BModbus TCP / OPC-UA via local gatewayReading + commands to the PLC through the bridge device
CRelay + flow-meter retrofitStart/stop and volume cut-off on machines without a PLC
DRead-only (telemetry)Live status and counters, no commands
EManual operator loggingThe operation enters the book just as complete
See all compatible equipment and brands

Safety

Designed so your cellar master signs off on it

The hardware E-stop always wins

If someone cuts the machine with the wall switch or the emergency stop, that wins over any remote command. Local industrial safety is never overridden.

Approval on critical commands

Starting a pump or a line needs approval from another authorized person, or the sender confirms with the machine's QR code that they are on the floor. You cannot approve your own command, even as the owner.

Physical presence via QR

Scanning the machine's QR code on the floor confirms a person is watching the hose. It replaces the second approval and is valid for 10 minutes, only for whoever scanned it.

Flow-meter cut-off loop

You ask for X litres and the bridge device cuts off at the target volume; if it loses the flow-meter reading, it stops the pump. Commands not executed within 10 minutes expire and are never retried automatically.

The differentiator

Integrated with your cellar book, not another dashboard

Dedicated automation systems record "the pump started at 14:30" and nobody knows which batch it was. In Cepaos, every commanded operation is automatically written to your cellar book and compliance records:

  • Full audit log: who sent the command, who approved, parameters and the machine's response
  • Bottling-line events are reconciled with the batch when the bottling run is confirmed
  • Each machine's profile keeps its history of events, cycles and maintenance

Pricing

from $229/mo

See plans and pricing

Frequently asked questions

Can I control my pump from my phone?

Yes. You can start, stop and request pumping X litres from your phone. Critical commands need approval from another authorized person or QR-verified presence on the floor; you cannot approve your own command.

Which equipment is compatible?

Pumps, presses, chillers, bottling lines, CIP systems, boilers, bench scales, in-line sensors, irrigation and more. There are five integration tiers: the manufacturer's native API, Modbus/OPC-UA via gateway, relay + flow-meter retrofit, read-only, and manual logging. No machine stays out of the book.

Is remote start safe?

The plant's physical emergency stop always wins over any remote command. On top of that: approval from another authorized person or QR-verified presence on critical commands, volume cut-off via flow meter, and automatic expiry: if a command is not executed within 10 minutes, it expires and nothing is retried automatically.

How much does it cost?

Connected Winery is a monthly add-on on top of your Cepaos plan, at list price for your market and currency. Available from the Domaine plan; included in Estate and in custom plans. Check the pricing page or talk to us about your case.

Do I need to replace my PLC or buy new equipment?

No. The integration uses what your machine already offers: the manufacturer's API or the existing PLC via Modbus/OPC-UA. For machines without a PLC, a relay + flow-meter retrofit is enough, and you can always start read-only or with manual logging without touching anything.

What happens if the internet goes down?

The machine stays under its local control: plant safety does not depend on the cloud. The bridge device stops accepting new commands, and those not executed within 10 minutes expire without being retried. When the connection returns, it sends the readings it stored.

Connect your first machine

Start with read-only (tier D) and enable commands when your team is ready.